Depending on who you ask, dry pipe sprinkler systems account for between 15-20% of the total number of installed fire sprinkler systems throughout the United States. Although they are less common when compared to a wet pipe sprinkler system, there are some cases when a dry pipe fire suppression system is more fitting. Find out what makes a dry pipe sprinkler system desirable and undesirable when taking into account certain considerations.

If you want to learn more, please visit our website JIANZHI.

When to Use a Dry Pipe Fire Suppression System

Dry pipe fire suppression systems are primarily used for two different scenarios: freeze risk and accidental water discharge. Dry pipe sprinkler systems are installed in areas subject to freezing temperatures when there is a risk of water freezing inside a sprinkler pipe and causing it to burst. Common examples would be attic spaces, loading docks, parking structures, and cold storage applications.

The other instance to install a dry pipe fire suppression system is to protect a critical or sensitive area where accidental water discharge would create substantial damage or downtime. These types of applications typically utilize a special type of dry pipe system known as a pre-action system. A pre-action sprinkler system usually requires a two-step activation process that includes a fire sprinkler activation plus another detection or initiating device to release water into the sprinkler system. These are used in electrical rooms, data centers/server halls, telecommunications, mission critical manufacturing, and cultural resource applications.

 

Disadvantages of a Dry Pipe Fire Suppression System

There are several disadvantages to using dry pipe sprinkler systems. Due to their added complexity and more stringent installation requirements, they are more expensive and time-consuming to install when compared to a wet pipe sprinkler system. Dry pipe fire suppression systems also require more testing and maintenance than a traditional wet pipe system. Dry systems require auxiliary drains and drum drips to be exercised regularly and full or partial trip testing of the dry pipe valve every 1-3 years.

System reliability and longevity should also be considered when comparing dry pipe systems with wet pipe systems. As you will find referenced throughout the ECS website, oxygen is the primary cause of corrosion and leaks in fire sprinkler systems. When maintained with supervisory compressed air, dry pipe systems have an essentially unlimited supply of oxygen whereas wet pipe systems have a finite supply of oxygen that is fully consumed within 3-4 months after the most recent drain and refill event.

Because of the excess available oxygen, dry pipe sprinkler systems corrode substantially faster than wet pipe systems unless a nitrogen-based corrosion control system is implemented. Internal corrosion debris can cause obstructions and restrict pipe diameters that result in diminished system performance and extended water delivery times during a fire event. The corrosion process also produces wall thinning and pin hole leaks that result in expensive system repairs and ultimately premature system replacement.

 

Advantages of a Dry Pipe Fire Suppression System

Although dry pipe fire sprinkler systems are more expensive to install, they can significantly reduce overall project costs in some applications. Using an attic space as an example, the installation of a dry pipe fire suppression system eliminates the need to insulate and heat the protected area. In many commercial buildings, unoccupied spaces require sprinkler protection where combustible construction materials are used. The cost difference between using non-combustible materials and installing a dry pipe fire suppression system can be significant.

In other instances, a dry pipe fire suppression system can be a comparatively inexpensive option when the alternative requires significant architectural or construction changes, such as a parking structure attached to an occupied building.

 

Conclusion

When comparing wet pipe systems with dry pipe systems, it is apparent that wet pipe systems are the preferred system type for building owners and operators. Wet pipe systems are less expensive to install and maintain and are more likely to perform reliably for a longer period of time.

There are some applications, however, where a dry pipe sprinkler system is appropriate &#; either it is protecting a space that cannot reasonably be heated and insulated, or it is protecting a space where the cost and risk associated with water damage far outweighs the disadvantages associated with a dry pipe fire suppression system. When dry pipe sprinkler systems must be used, ECS offers dry pipe corrosion control solutions that eliminate reliability and longevity disadvantages.

Pros and cons of fire extinguisher types

Water &#; Suitable for Class A Fires

Water has excellent cooling properties but is only suitable for use on Class A fires.

Our Green Series Water units have been designed for the Irish market and to compliment all the requirements contained within Irish Standard 291. They are a direct alternative for the Foam AFFF when there is no class B risk.

 

Foam AFFF &#; Suitable for Class A and B Fires ***AFFF  should only used where a risk assessment dictates so.

**When the new restrictions arrive, there will be a total prohibition on the purchase, training, testing and application of AFFF and any remaining inventory will have to be managed as hazardous waste. In addition, if your total inventory of handheld AFFF Extinguishers exceeds 50 Kg you will be  required to notify the EPA. Read More &#;

Class A &#; combustible solids (paper, wood)
Class B &#; flammable liquids (petrol, diesel, spirits, paint)

Pros

Higher A rating than water, so more effective on combustible solids. For example, a 6lt Foam has the extinguishing capability of a 9lt Water.

Foam discharge is easier to clean up than powder.

Foam is not as conductive as water, so it won&#;t cause as much damage if sprayed on electrical equipment.

Cons

It can be susceptible to frost.

 

ABC Powder &#; Suitable for Class A, B, C and Electrical Fires

Class A &#; combustible solids (paper, wood)
Class B &#; flammable liquids (petrol, diesel, spirits, paint)
Class C &#; flammable gases (methane, butane

Pros

Ideal as a multipurpose extinguisher for home and work.

Twice as effective as Foam on Class A fires, for example: a 6kg Powder is rated 27A, whereas a 6lt Foam is rated 13A.

Not as susceptible to frost as water-based extinguishers.

Very effective for burning and free-flowing liquids.

When powder is applied to hot smouldering surfaces, the particles fuse together and swell. This forms a barrier which excludes oxygen and prevents reigniting.

Cons

For more fire fighting fittingsinformation, please contact us. We will provide professional answers.

Can be messy, as it&#;s a fine powder. Clean up can be costly and time-consuming, so consideration should be given where misuse/accidental use would be an issue.

Reduces visibility when discharged, so consideration required when placing near escape routes, stairwells, etc.

May aggravate respiratory conditions when discharged.

Limited cooling properties.

While Powder is safe for use on electrical fires, it can cause corrosion.

 

CO2 &#; Suitable for Class B and Electrical Fires

Class B &#; flammable liquids (petrol, diesel, spirits, paint)

Pros

Smothers fire quickly in draught-free conditions.

A non-conductor, so can be used on live electrical equipment.

Leaves no residue and is not as damaging to electrical equipment as powder.

Cons

It&#;s an asphyxiate, so care should be exercised when using in confined spaces.

Limited cooling properties and no protection against reigniting.

A non-insulated horn can cause frost burn if user accidentally touches the horn when in use.  Frost- free horns offer some protection against this (a frost free horn has a honeycomb ring on the internal lining; non-insulated horns have a single layer of plastic).

 

Wet Chemical &#; Suitable for Class F Fires

Class F &#; cooking oils and fats

 

Powder &#; Suitable for Class D Fires

Class D &#; metals
Specialist Class D Dry Powder for Flammable Metals.

 

Monnex &#; Suitable for Class B and C Fires

Class A &#; combustible solids (paper, wood)
Class B &#; flammable liquids (petrol, diesel, spirits, paint)

Pros

High performance specialist powder extinguisher.

Also safe to use on flammable chemicals.

Ideal for garages, fuel depots, airports, motor racing events and chemical stores.

 

Automatic Extinguisher

Dry powder extinguisher ideal for use on oil or gas burners. Heat activated. No manual intervention required.

 

 

 

Halon

Under the European Council Regulation /, Halon portable fire extinguishers are no longer permitted for use in the European Union due to their ozone-depleting substances. Exceptions include use in civil aircraft, the armed forces and the emergency services.

Class F &#; cooking oils and fats

Are you interested in learning more about elbow pipe? Contact us today to secure an expert consultation!