When it comes to ball valve sizes, theres more to it than meets the eye. For some applications, it may be relatively straightforward, but selecting the ideal ball valve dimensions may require considering numerous factors beyond the pipe size.
Contact us to discuss your requirements of feeding ball valve. Our experienced sales team can help you identify the options that best suit your needs.
To ensure the best performance and longevity of a valve, youll need to consider the:
The importance of choosing the correct valve size, style and material cannot be overstated. A poorly selected valve may lead to premature or unexpected failure, with potential consequences such as cavitation, flashing, erosion, vibration or corrosion. By paying close attention to ball valve dimensions and selecting the appropriate components, you can significantly reduce the likelihood of valve failure and optimize system performance.
In this guide, well help you navigate the essential aspects of ball valve dimensions, providing valuable insights to help you make informed decisions when selecting the ideal valve for your application.
Figure 1: Ball valves with different orifice sizes
Understanding ball valve sizing is essential for industries using fluid control systems. There are many parameters to consider when sizing a ball valve, including the fluid type, flow rate, pressure, velocity, and operating conditions. This article comprehensively discusses ball valve sizing, including the key factors to consider, different methods, and sizing charts for common applications. Read our ball valve overview article for more information on the design and working of ball valves.
There are essential considerations to make when sizing ball valves for various applications, including pressure parameters, valve-to-pipe size relationships, valve connections, media velocity, and concerns about cavitation.
When sizing ball valves for various applications, it's essential to consider the flow rates, often represented by the Cv and Kv values. These values indicate the valve's flow capacity, essentially describing how much fluid can pass through the valve under a given pressure. A higher Cv or Kv value means the valve can pass more fluid with less resistance, thus offering better flow control. Here are some flow considerations to remember:
Flanged connections are common and are typically used per the line's specifications. However, for ball valves with a diameter of 1½ inches or less, a minimum rating of 300 ANSI (American National Standards Institute) is recommended, as these valves are used in high pressure applications, such as oil and gas production, chemical processing, and power generation. The ANSI 300 rating indicates that the valve can handle a maximum pressure of 49.6 bar (720 psi) at ambient temperature.
A line velocity of about 3 m/s (10 ft/s) is recommended for non-abrasive, clean liquids. However, it is crucial to keep the velocity as low as possible for abrasive fluids to minimize wear and tear on the valve. The velocity should still be high enough to prevent the abrasive particles from settling out of the fluid. Read our valves for high viscosity fluids article for more details.
It's recommended to have a straight section of pipe after the valve to prevent cavitation. Cavitation refers to the forming and collapsing of vapor bubbles in a fluid, which can damage the valve. This allows the fluid to flow smoothly, reducing the likelihood of disruption. A 'T' junction or elbow immediately after the valve can disrupt the flow and lead to cavitation.
Figure 2: Ball valve bore
Use our Kv or Cv calculator to calculate the flow rate required for a given medium and pressure drop. When choosing valves, select a Cv (or Kv) value closest to the calculated result, typically rounding down to the nearest number unless a specified maximum pressure differential of a valve is exceeded. An oversized valve can cause water hammer and premature wear on the valve packaging. Conversely, an undersized valve may not provide enough media flow and exceed the available differential pressure between the ports.
Table 1 shows the Cv and Kv values against the standard ball valve sizes for three-way reduced port threaded ball valves. If the calculated Cv value is 15, choose a ball valve with ½ inch size as it is closest to the rated Cv value (15.2) for the size. If the calculated Cv value is 110, choose a ball valve size of 2 inches, and so on.
The Cv and Kv values of different types of ball valves are given in Tables 1-5.
Table 1: Full port ball valve size chart in mm (Cv chart)
Size BSP (in inch) DN (mm) Cv when fully open Kv, when fully open 1/4 8 18 15.35 3/8 10 20 17.06 1/2 15 23 19.6 3/4 20 55 46.9 1 25 95 81.03 1 1/4 32 155 132.2 1 1/2 40 260 221.8 2 50 440 375.3 2 1/2 65 710 605.6 3 80 895.6 4 100 .1Table 2: 3-way full bore ball valve Cv chart
Size (in inch) Size (in mm) Cv Kv (m3/h) 1/2 12.7 15.2 13 3/4 19 23.3 20 1 25.4 45.5 39 1 1/4 31.75 58.4 50 1 1/2 38.1 112 96 2 50.8 224.1 192 2 1/2 63.5 308.1 264 3 76.2 409.6 351 4 101.6 762.1 653Table 3: 3-way reduced port threaded ball valve Cv and Kv chart
Size (in inch) Size (mm) Cv (gallons/min) Kv (m3/h) 1/4 6.35 12.8 11 3/8 9.525 12.8 11 1/2 12.7 15.2 13 3/4 19.05 17.5 15 1 25.4 36.2 31 1 1/4 31.75 45.5 39 1 1/2 38.1 72.4 62 2 50.8 120.2 103 2 1/2 63.5 239.2 205 3 76.2 270.7 232 4 101.6 480.8 412A V-port ball valve has a contoured V-shaped ball inside that precisely controls flow rates in industrial applications.
Table 4: V-port ball valve Cv dimension chart
Valve size(inch)
Valve size (mm) Ball angle 15% 20% 30% 40% 50% 60% 70% 80% 90% 100%1/2
12.7
30° 0.1 0.1 0.2 0.3 0.5 0.8 1.1 1.6 2.2 2.6 60° 0.1 0.1 0.3 0.5 0.9 1.4 2 3.3 4.4 63/4
19.05
30° 0.1 0.2 0.5 0.7 1.1 1.8 2.4 3.3 4.5 5.4 60° 0.1 0.2 0.7 1 1.7 2.8 4 6.5 9 121
25.4
30° 0.1 0.3 0.8 1.3 2.3 3.5 5.1 9.8 8.5 10 60° 0.2 0.4 1.1 1.8 3.4 5.3 7.9 12.3 15.3 211 1/4
31.75
30° 0.2 0.4 1.1 2 3.7 5.5 8 10 13 15 60° 0.2 0.6 1.8 3 5.5 9.5 12.8 19 26 391 1/2
38.1
30° 0.3 0.6 1.6 3 5 7.5 11 14 17 20 60° 0.4 0.8 2.5 4 8 13 19 27 40 522
50.8
30° 0.4 1.2 3.8 6 10 15 23 31 43 60 60° 0.4 1. 4.6 9 16.5 27 39 55 83 1102 1/2
For more information, please visit petrochemical valve components.
63.5
30° 0.4 1 4 8 12 18 28 37 62 75 60° 0.4 1.5 5 10 21 34 53 75 103 1503
76.2
30° 0.5 1.2 4 8 14 23 33 46 65 82 60° 0.5 2.5 6 4 25 40 65 91 128 1654
101.6
30° 0.6 2 6 15 29 48 71 100 130 159 60° 0.7 3 11 25 40 59 90 141 212 3566
152.4
30° 0.9 3.2 14 33 60 103 155 220 280 350 60° 2 5 22 60 110 190 285 416 586 800Table 5: V-port ball valve Kv dimension chart
Valve size(inch)
Valve size (mm) Ball angle 15% 20% 30% 40% 50% 60% 70% 80% 90% 100%1/2
12.7
30° 0.08 0.08 0.17 0.25 0.42 0.68 0.93 1.36 1.87 2.2 60° 0.08 0.08 0.25 0.43 0.77 1.19 1.706 2.8 3.7 5.123/4
19.05
30° 0.08 0.17 0.42 0.6 0.93 1.5 2.04 2.8 3.8 4.6 60° 0.08 0.17 0.59 0.85 1.45 2.4 3.412 5.5 7.7 10.231
25.4
30° 0.08 0.25 0.68 1.1 1.96 2.98 4.3 8.3 7.25 8.53 60° 0.17 0.34 0.93 1.5 2.9 4.5 6.73 10.5 13.05 17.911 1/4
31.75
30° 0.1 0.34 0.94 1.7 3.16 4.7 6.82 8.53 11.1 2.8 60° 0.17 0.51 1.53 2.6 4.7 8.1 10.9 16.2 22.1 33.31 1/2
38.1
30° 0.25 0.51 1.36 2.5 4.2 6.4 9.4 11.9 14.5 17.06 60° 0.34 0.68 2.13 3.4 6.8 11.1 16.2 23.03 34.12 44.32
50.8
30° 0.34 1.02 3.24 5.1 8.5 12.8 19.6 26.4 36.7 51.2 60° 0.3 0.8 3.9 7.7 14.07 23.03 33.2 46.9 70.7 93.82 1/2
63.5
30° 0.3 0.8 3.4 6.8 10.2 15.3 23.9 31.5 52.9 63.9 60° 0.3 1.3 4.3 8.5 17.9 29 45.2 64 87.8 127.93
76.2
30° 0.4 1 3.4 6.8 11.9 19.6 28.1 39.2 55.4 69.9 60° 0.4 2.1 5.1 3.4 21.3 34.1 55.4 77.6 109.2 140.74
101.6
30° 0.5 1.7 5.1 12.8 24.7 40.9 60.5 85.3 110.9 135.6 60° 0.6 2.55 9.4 21.3 34.1 50.3 76.8 120.3 180.8 303.66
152.4
30° 0.7 2.73 11.9 28.1 51.2 87.8 132.2 187.7 238.8 298.5 60° 1.7 4.3 18.7 51.2 93.8 162 243.1 354.8 499.8 682.4Valve sizing is selecting the appropriate valve dimensions and characteristics to ensure it can effectively control fluid flow within a piping system based on specific application requirements.
Sizing a ball valve involves considering factors such as flow rates, pressure drop, pipe size, and application-specific requirements to select the appropriate valve size and configuration that can effectively control fluid flow within a system.
The Cv (flow coefficient) of a ball valve represents its ability to control fluid flow through it and is typically provided by the valve manufacturer as a numerical value, with higher Cv values indicating greater flow capacity.
Cv (flow coefficient) for valves is calculated using: Cv = Q / sqrt(deltaP). Q is the flow rate in GPM, deltaP is the pressure drop in psi.
To measure valve size, determine the nominal pipe size (NPS) or diameter of the valve's inlet/outlet connection using a tape measure or calipers. Common NPS sizes include 1/2", 3/4", and 1".
Are you interested in learning more about pneumatic control valve from china manufacturer? Contact us today to secure an expert consultation!