Glycol is a viscous, colorless and odorless synthetic liquid. Its a common antifreeze ingredient for mechanical cooling systems and automotive engines. It can absorb and release large amounts of heat while maintaining a consistent temperature. This unique ability makes it suitable for beverage chillers and other industrial refrigeration applications.
There are two main types of glycol:
Glycol is an asset for HVAC cooling systems, primarily due to the way it reacts with water. It can help keep pipes from freezing in frigid temperatures. Water has a freezing point of 32 degrees Fahrenheit. The addition of glycol can lower waters freezing point by as much as minus 60 degrees Fahrenheit.
Thanks to glycol, cooling systems can maintain colder temperatures than they could with only water. Thats why glycol cooling systems are a popular solution in food processing facilities, manufacturing plants and other industrial settings. Learn more about how glycol benefits cooling systems.
Glycol was a game-changer for various applications due to its versatility. It allows manufacturers to customize coolants for numerous uses. Lets explore the origins of glycol and its impressive cooling properties below.
Up until the early 20th century, alcohol was the standard ingredient for automotive antifreeze. These antifreeze products were typically made of methanol, also known as wood alcohol. Alcohol has a lower freezing point than water, making it the antifreeze of choice back then.
However, alcohol can spell trouble for metal engine components, causing extreme corrosion and rust. Early water cooling systems were also open, allowing the alcohol to evaporate gradually. If operators didnt constantly top up their systems, the coolant could freeze or the engine could overheat.
In response to this issue, glycerol was introduced as an antifreeze in the early s. But it was expensive to produce, and eventually ethylene glycol was its replacement.
French chemist Charles-Adolphe Wurtz first produced ethylene glycol in , making it one of the oldest antifreeze solutions. However, it wasnt commercialized until . It was manufactured on a small scale during World War I, serving as both a coolant and an ingredient for explosives.
Ethylene glycol became available as an automotive antifreeze in , and its military use continued into World War II. To prevent damage to metal vehicle components, manufacturers added corrosion inhibitors to the ethylene oxide and water mixture.
Corrosion inhibitors help the liquid coolant remain alkaline (having a pH above 7). However, acidity naturally increases over time, so coolant must be changed regularly to avert corrosion.
When ethylene oxide became cheaply available, widespread ethylene glycol manufacturing began in . Its large-scale production sparked a minor revolution in aircraft engineering. When manufacturers substituted ethylene glycol for water as an engine coolant, they discovered its high boiling point enabled smaller radiator operation at higher temperatures.
Before ethylene glycols widespread availability, aircraft manufacturers tried using evaporative cooling systems that used water at high pressure. These systems were unreliable and highly susceptible to damage during combat. They occupied substantial space on planes, making them easy targets for gunfire.
Ethylene glycol has a boiling point of 386 degrees Fahrenheit and a freezing point of 10 degrees Fahrenheit. Due to these characteristics, manufacturers found it had a broad array of industrial uses. Ethylene glycol on its own doesnt conduct heat as efficiently as water. When combined with water, however, its heat transfer and functional range expanded significantly. Besides providing exceptional heat transfer, ethylene glycol can also suppress algae growth in heat transfer equipment.
Wurtz also produced propylene glycol in , but the substance wasnt commercialized until . While propylene glycol cant rival the heat transfer of its ethylene counterpart, it is also less toxic. This attribute makes it ideal as a solvent in food, cosmetic and pharmaceutical products.
Propylene glycols main drawback is that its often made from petroleum, a nonrenewable resource. Over 1 million tons of petroleum are needed to meet worldwide demand annually. In , two American chemical engineers from the University of Wisconsin-Madison James Dumesic and Rady Cortright created a process that converted corn-based lactic acid to propylene glycol. This process omitted the need for petroleum-based chemicals, lowering the cost to manufacture propylene glycol.
Today, propylene glycol has a multitude of uses, acting as a preservative, stabilizer, freeze point modifier and wetting agent.
Glycol coolers serve an extensive range of industries, from automotive to brewing. They offer outstanding performance in low-temperature environments, like ice rinks and food processing facilities. Here are some of glycols common cooling applications.
Glycol is an excellent antifreeze for automobiles and industrial water systems. It can also serve as a de-icing fluid for aircraft and windshields because of its low freezing point.
The brewing and distilling industry relies on glycol chillers, as it requires consistent and controlled temperatures. Any fluctuations can negatively impact the final product quality. Propylene glycol chillers help maintain and regulate container temperatures, making them a must for:
Dairy products require a proficient cooling system to prevent bacterial growth. Milk is pumped from cows into cooling units, which store the milk until processing. Each stage of this process requires precise temperature control. The raw milk must maintain a consistent temperature to prevent bacteria and spoilage.
Grocery stores must maintain consistent temperatures in cooling units to prevent spoilage. Likewise, fruits, vegetables and other perishables must remain fresh during packing and shipping. Propylene glycol chillers are essential to meet produce packaging, shipping and storage requirements.
Because glycol chillers can achieve a lower freezing point than water, they can be installed in outdoor ice rinks, even in warmer climates. Mats are typically placed beneath the rinks surface and pumped with glycol. Water is then sprayed over the mats and freezes.
How do glycol chillers help maintain cool temperatures in closed loop systems? Here are the different steps that must take place.
The first step is installing a glycol chiller a refrigeration system that cools a tub of glycol in a closed loop water system. The glycol moves through a closed piping or tubing circuit that connects to the chiller. This process helps reduce the glycol temperature of whatever is hooked up to the system.
If you are looking for more details, kindly visit Glycol for Refrigeration.
Heat exchangers must be attached to the closed loop systems input and output to achieve efficient cooling. Different cooling systems use different types of heat exchangers, such as:
The heat exchangers should connect to the main cooling line that circulates the water and glycol mixture.
The glycol cools the vessels as it circulates through the heat exchanger, successfully cooling the vessel. A closed loops cooling system can vary depending on its configuration and your operations. A knowledgeable water treatment provider can work with you to install a safe, efficient glycol cooling system in your facility.
A glycol chillers powerful antifreeze properties can provide consistent, reliable performance in various operations. When considering the benefits of a glycol chiller, this cooling system has the upper hand over conventional ice- and water-based industrial cooling processes. Here are some advantages glycol cooling can bring to your facility.
Glycol can accommodate even the tightest temperature ranges. Unlike traditional refrigeration systems which use direct expansion evaporators glycol systems generally use flooded evaporator coils. These coils provide higher temper holding times, quicker temperature pull downtimes and improved recovery times after defrosting.
In turn, glycol cooling helps yield fresher and higher-quality products, reduces wastage and boosts product shelf life. With frozen and refrigerated foods, for instance, glycol cooling offers consistent temperatures that prevent bacteria, rotting and spoilage. It ensures fresher, better-tasting products.
Glycol helps inhibit bacterial growth and corrosion in a closed loop systems pipes. These contaminants can produce high levels of metal oxides, leading to fouling (degraded heat transfer) and other issues. These problems can lead to failure and costly repairs.
Overheating can also cause equipment to malfunction or break down, raising repair costs and setting back operations significantly. A glycol chiller helps protect equipment from microbiological growth, corrosion and heat-related damage.
Additionally, glycol cooling systems typically encounter fewer refrigerant leaks due to increased efficiency throughout the unit. Glycol cooling also saves money by reducing the volume of refrigerant in the system.
Glycol is a biodegradable refrigerant, making it an environmentally friendly option for closed loop cooling applications. Additionally, glycol chillers have multiple energy-efficient options, such as:
Glycol chillers can become clogged with dirt and sludge over time. Additionally, your glycol systems pipes can start to corrode due to acidity, as well as particles or solids introduced when the system was last worked on. Cleaning a glycol system is important to maintain peak performance and longevity. Here are some tips for cleaning your glycol system to keep it free of foreign matter.
Turn off the chiller, then use a hose to rinse the coils gently from the outside. Rinsing helps remove dirt, dust and other debris that may have accumulated on the coil.
Remember to clean the area around the chiller, as well. This helps ensure any rinsed-off debris doesnt get sucked back into the condenser later on. If the condenser is exceptionally dirty, many hardware stores have special coil cleaners. Follow the packages directions to ensure youre using it correctly.
Wipe down the inside of the chiller and look for oil residue. Should you spot any, there may be a refrigerant leak. Be sure to contact a service technician right away to address this issue.
Glycol breaks down over time, rendering the metal more vulnerable to corrosion. Closed loop water requires ongoing chemical treatment, even if the glycol has an inhibitor.
An experienced water treatment provider can help you select and apply treatment chemicals based on your systems needs. Chemicals limit or remove harmful corrosion deposits. This process improves heat transfer and allows the liquid to flow more smoothly through the pipes. A water treatment expert can also help you flush the pipes after chemical treatment.
If youre looking to install a glycol system for your closed loop or you require maintenance on an existing setup its best to consult a company with decades of industry expertise.
At Chardon Laboratories, we provide a variety of closed loop water treatment services. We use ethylene glycol in most of our closed loop applications. While propylene glycol is less toxic and more eco-friendly, it doesnt achieve the same freezing point and cooling abilities as ethylene.
Our ISO-certified technicians perform comprehensive closed loop maintenance, preventing leaks and other costly issues. We can help you create a customized water treatment plan based on your unique requirements and operations. This plan includes:
Let Chardon Labs help your closed loop system achieve peak performance, efficiency and longevity. Contact us today and learn more about our closed loop water treatment services!
While glycol refrigeration systems are nothing new, the popularity of these systems have been significantly increasing. Not only are glycol refrigeration systems highly reliable, but with recent changes to refrigerant pricing, the commitment to sustainable refrigeration approaches, and environmental concerns, many people are seeing the benefits of glycol refrigeration systems.
Referred to as antifreeze, glycol is a class of organic compounds that belong to the alcohol family. Glycol has excellent heat transfer properties and is able to remove large amounts of heat quickly. Due to its excellent heat transfer properties, glycol is ideal for cooling and chilling applications. When mixed with water, glycol slows the rate of freezing and helps to maintain temperature consistency in the application.
Glycol systems use fully flooded evaporator coils, unlike conventional refrigeration systems which use direct expansion evaporators. This difference results in glycol systems having a faster temperature pull downtime, increased temperature holding times, and improved recovery times after defrost. It also results in increased product shelf life, reduced waste, and fresher products. Glycol is a natural refrigerant, making it much more environmentally friendly, and can also work to inhibit corrosion and bacterial growth within the pipes of a system.
Due to increased efficiencies throughout a system, glycol refrigeration systems encounter fewer refrigerant leaks. The volume of refrigerant in the system is significantly reduced which can also provide significant savings in cost. With a reduction in the system complexity and failure points on a glycol system, servicing and downtimes are reduced along with maintenance costs. Failures in a glycol system on one refrigerated space are unlikely to affect the integrity of other refrigerated spaces on the system.
Keeping products at a consistently low temperature can be expensive and require regularly scheduled monitoring. The introduction of glycol refrigeration systems in their varied sizes has made it easier and less expensive to produce high-quality products without the need for continually checking the cooling process.
For more Glycol Unitsinformation, please contact us. We will provide professional answers.